PROBEST DXC20+PUVCOD-900 UV254 Spectrometer Organic Online Analyzer, OEM Reagent-Free COD BOD TOC Water Monitoring System for Wastewater
Product Description
PROBEST DXC20+PUVCOD-900 UV254 organic online analyzer supports OEM, reagent-
free COD/BOD/TOC testing. Auto-clean probe, multi-install controller, 4-20mA relay output for sewage, industrial & fishery water continuous
PROBEST DXC20+PUVCOD-900 UV254 spectrometer organic online analyzer is an OEM-support integrated water quality monitoring system, consisting of DXC20 digital controller and PUVCOD-900 UV immersion sensor. Based on SAC254 ultraviolet absorption principle, it real-time converts water organics into COD, BOD, TOC data without reagents. Equipped with auto-clean probe, visual alarm, multi-mount controller and MODBUS RS485 communication, it realizes long-term unattended online monitoring for wastewater plants, industrial discharge, surface water and aquaculture water.
H1:PROBEST DXC20+PUVCOD-900 UV254 Spectrometer Organic Online Analyzer | OEM Reagent-Free COD BOD TOC Monitoring System
H2:1. Measurement Principle of DXC20+PUVCOD-900 Organic Online Analyzer
H2:2. Core Product Advantages & Features
H3:2.1 Integrated Probe + Controller Complete Monitoring System
Matching DXC20 dedicated display controller + PUVCOD-900 UV organic sensor, one set realizes real-time display, data output and over-limit alarm of COD/BOD/TOC, plug-and-play without extra supporting equipment.
H3:2.2 Direct Immersion Probe, No Sampling & Pretreatment
Submersible probe can be directly put into sewage tanks, drainage outlets, rivers and aquaculture ponds, no sampling pump, flow cell or pre-filter required, simplifying field construction.
H3:2.3 Reagent-Free Operation, Zero Secondary Pollution
No chemical reagents consumed during long-term operation, no hazardous waste discharge, meets global environmental protection standards and lowers long-term operating expenditure.
H3:2.4 Automatic Sensor Cleaning & Low Maintenance Cost
Built-in self-cleaning device regularly cleans the optical window to resist sludge, algae and biofilm adhesion, stabilize measuring accuracy and reduce manual maintenance workload.
H3:2.5 Multi-Mount DXC20 Controller with Sunlight Visible LCD
The controller supports wall-mounted, panel-mounted and pipe-mounted installation; 128*64 dot matrix LCD with high-brightness backlight works normally under direct sunlight for outdoor monitoring stations.
H3:2.6 Visual Alarm & Multi-Channel Signal Output
Built-in visual alarm system for abnormal organic load early warning; equipped with 3-way programmable 4-20mA analog output and 3-way relay switch, convenient for linkage with dosing pumps and control valves.
H3:2.7 Stable MODBUS RS485 Digital Communication
Standard MODBUS RS485 protocol, compatible with SCADA, industrial PLC, data recorders and remote environmental monitoring cloud platforms for remote data transmission.
H3:2.8 Neutral OEM Customization Support
Provide neutral OEM service without brand logo; support customized cable length, measuring range, output parameters and housing labeling to meet distributors and system integrators’ private brand demands.
H3:2.9 Wide Application Temperature & High Waterproof Grade
Sensor IP68/NEMA6P, controller IP66/NEMA4X; optional SUS316L stainless steel (freshwater) or titanium alloy (seawater) probe body for various water quality scenarios.
H2:3. Typical Application Scenarios
Municipal wastewater treatment plant: Real-time COD/BOD/TOC monitoring of inlet and outlet water, organic load continuous tracking in biochemical tanks
Industrial wastewater discharge: Chemical, food, printing and textile factory effluent online pollution monitoring
Surface water environment supervision: River, lake, reservoir long-term in-situ organic matter detection
Fishery & aquaculture wastewater: Breeding water organic pollutant real-time early warning
Environmental online monitoring stations, floating water quality buoys, factory automatic drainage monitoring systems
H2:4. Complete Technical Specifications
H3:4.1 PUVCOD-900 UV Sensor Parameters
| Item | Technical Data |
|---|---|
| Measuring Range (KHP Calibration) | COD:0–2000mg/L(2mm),0–1000mg/L(5mm),0–90mg/L(50mm) BOD:0–1500mg/L(2mm),0–750mg/L(5mm),0–60mg/L(50mm) TOC:0–800mg/L(2mm),0–400mg/L(5mm),0–35mg/L(50mm) |
| Accuracy | ±5% (KHP Standard Solution) |
| Repeatability | ±2% (KHP Standard Solution) |
| Resolution | 0.01mg/L |
| Max Working Pressure | ≤0.4Mpa |
| Sensor Housing | SUS316L (Fresh Water); Titanium Alloy (Marine Seawater) |
| Cable Material | PUR Waterproof Cable |
| Cable Length | Standard 10m, Max extendable to 100m |
| Storage Temp | -15℃ ~ 50℃ |
| Measuring Temp | 0℃ ~ 45℃ (Non-freezing) |
| Protection Class | IP68 / NEMA6P |
| Size & Weight | Diam 69mm × L365mm, 3.2KG |
H3:4.2 DXC20 Controller Parameters
| Item | Technical Data |
|---|---|
| Display | 128*64 Graphic LCD with LED high backlight, sunlight readable |
| Power Supply | AC 85–500VAC / DC 9–36VDC |
| Housing Material | Cover: PA66+GF25+FR; Lower shell: Aluminum alloy powder coating |
| Analog Output | 3 programmable 4-20mA channels |
| Relay Output | 3 programmable relay switches for alarm linkage |
| Communication | MODBUS RS485 |
| Storage Temperature | -20℃ ~ 70℃ |
| Working Temperature | -15℃ ~ 60℃ |
| Protection Grade | IP66 / NEMA4X |
| Dimension | L145mm × W125mm × H162mm |
| Weight | 1.35KG |
H2:5. System Advantages vs Traditional COD Monitoring Equipment
Full integrated system: One-stop solution of sensor + display controller, convenient for project matching
Neutral OEM available: Support private label, help distributors build own water quality instrument brand
No reagent cost: Save chemical purchasing, transportation and waste liquid disposal expenses
Direct immersion measurement: Avoid sampling loss and manual testing errors
Auto-clean probe: Greatly reduce on-site maintenance labor cost
Multi-signal output: Analog + relay + RS485, flexible access to all industrial control systems
Dual corrosion-resistant probe materials: Adapt to freshwater and high-salinity marine water
Multi-install controller: Adapt to various monitoring station layout requirements
H2:6. FAQ Module
Q1: Does PROBEST DXC20+PUVCOD-900 support OEM service?
Yes, we provide neutral OEM customization without PROBEST logo, support customized packaging, labeling and parameter settings for global distributors and system integrators.
Q2: What organic indicators can this online analyzer detect?
It can real-time output COD, BOD and TOC three core organic pollution indexes via KHP calibration.
Q3: Can the DXC20 controller be installed on pipeline or cabinet panel?
Support wall-mounted, panel-mounted and pipe-mounted three installation methods for different site conditions.
Q4: Is the probe suitable for seawater monitoring?
Optional titanium alloy probe housing with strong anti-corrosion performance for ocean and high-salinity wastewater.
Q5: Does the system need regular manual cleaning?
The PUVCOD-900 probe has automatic cleaning function, only simple periodic inspection is required.
H2:7. Why Choose PROBEST DXC20+PUVCOD-900 OEM UV COD Monitoring System