PMI800-EC China Probest Portable Laboratory And Online Process EC Conductivity Probe Sensor Analyzer Water Testing Tool
Product Description
Warmly welcome online / on-site meeting with us to show you around our factory and know each other better.
PMI800 Series Portable Water Analyzer
Introduction
PMI800 when used with portable electrodes, the PMI800 portable analyzer can measure a variety of parameters such as pH, ORP, Conductivity (convertible Salinity & TDS), Dissolved oxygen, Turbidity, Suspended solids, Chlorophyll, Blue-green algae etc. The connected electrode type can be automaticallyidentified;singlechannelanddualchannelconfigurationsareavailable.Ithastheadvantagesofcomfortableoperation,convenienttestingandwideapplication.
Main features
⊃2; The host with IP67 protection rating.
⊃2; 3.5-inch color screen display, interface menu design is beautiful, easy to operate;
⊃2; Ergonomic curve design, suitable for hand grip, with rubber non-slip hand strap, not easy to slip in wet environment.
⊃2; With data storage function, storage space 8G, and data export through USB interface.
⊃2; Built-in rechargeable battery and charging directly via USB without disassembling the battery.
⊃2; Automatically identify the connected sensor type and the reading interface automatically adapts.
⊃2; The sensor can be parameterized and calibrated.
Electrode Parameters
Temp. | Principle | Thermal method | |
Range | 0℃-60℃ | ||
Resolution | 0.01℃ | ||
Accuracy | ±0.5℃ | ||
pH | Principle | Glass electrode method | |
Range | 0-14 pH | ||
Resolution | 0.01 pH | ||
Accuracy | ±0.1 pH | ||
ORP | Principle | Glass electrode method | |
Range | -2000mV-+2000mV | ||
Resolution | 1mV | ||
Accuracy | ±2mV(Electronic component) | ||
Conductivity (convertible Salinity & TDS) | Principle | Conductivity cell method | |
Range | 0-20000us/cm(K=1) | ||
Resolution | 0.1uS/cm-0.01mS/cm(base on range) | ||
Accuracy | ±1.5% or ±2 us/cm,bigger one | ||
Dissolved oxygen | Principle | Fluorescence method | |
Measure Range | 0-20 mg/L;0-20 ppm;0-200% | ||
Resolution | 0.1%/0.01mg/l | ||
Accuracy | ±3% or ±0.3 mg/L, the bigger one | ||
Turbidity | Principle | Light scattering | |
Measure Range | 0.1-1000NTU | ||
Resolution | 0.01-0.1NTU,base on range | ||
Accuracy | ±5% or 0.3NTU bigger one | ||
Suspended solids | Principle | Light scattering | |
Measure Range | 0.01-20000mg/L;0.01-45000mg/L; 0.01-120000mg/L | ||
Resolution | 0.01-1 mg/L,base on range | ||
Accuracy | Not more than ±5% measured(Depends on sludge homogeneity) | ||
Chlorophyll | Principle | Fluorescence method | |
Measure Range | 0-500 ug/L | ||
Resolution | 0.01 ug/L | ||
Accuracy | ± 5% of the signal level of 1 ppb rhodamine B dye | ||
Linearity | R2 >0.999 | ||
Blue-green algae | Principle | Fluorescence method | |
Measure Range | 0-300,000cells/mL | ||
Resolution | 20 cells/mL | ||
Accuracy | ±10% of the signal level of 1 ppb rhodamine B dye | ||
Linearity | R2 >0.999 | ||
COD | Principle | UV absorption method | |
Measure Range | 0-500mg/l COD (5mm) | ||
Resolution | COD/BOD/TOC:0.01 mg/l | ||
Accuracy | 5% (using KHP calibration) |