Availability: | |
---|---|
Quantity: | |
MUC200
PROBEST
China Factory Wholesale Testing Instrument Water Quality Analyzer Manufacturer
Measurement Principle:
MUC-200 multi-parameter transmitter can simultaneously monitor multiple different parameters according to different needs of customers, including temperature / PH / ORP / conductance / dissolved oxygen / turbidity / sludge concentration / chlorophyll / Blue-green algae / UVCOD / ammonia nitrogen and so on. The transmitter has a data storage function, and the user can also realize 4-20 mA analog output through interface configuration and calibration of the transmitter; realize relay control and digital communication.functions. Up to 7 sensor could be connected.
The multi-parameter transmitter can realize online monitoring of multiple different parameters at the same time through optional sensors according to different needs of customers, including temperature / PH / ORP / conductance / dissolved oxygen / turbidity / sludge concentration / chlorophyll / blue-green algae / UVCOD / UVNO3 / ion ammonia nitrogen / transparency / residual chlorine and other parameters. The transmitter software interface parameter display realizes self-adaptation,and has data storage and
Features:
1.Up to 7 sensors of our company can be connected at the same time to improve integration and reduce operation and maintenance costs
2. Strong versatility, all digital sensor interfaces are common, and analog sensors can be configured with different modules according to different sensor types
3. The plug and play of the sensor is realized, and the electrode installation and replacement are fast and convenient
4. With 7-inch color touch screen, the operation interface is simple, easy learn, reliable system, low maintenance;
5. pH, ORP, conductivity sensor cleaning and activation is simple, and the balance speed is fast
6. Dissolved oxygen sensor adopts breakthrough fluorescence method technology, basically no maintenance, and comes with NTC temperature compensation function
7. The turbidity, sludge concentration sensor uses ISO7027 standard method (infrared light scattering technology), which can eliminate the influence of the color of the sample, and can be equipped with a cleaning brush function
8. Chlorophyll sensor and blue-green algae sensor measure the target parameters based on the fluorescence of the pigment, which can be identified before the potential water bloom causes the impact, without the need for extraction or other treatment, rapid detection, to avoid the impact caused by the water samp
Applications:
1.Online monitoring of multi-parameter water quality in surface water, drinking water sources and aquaculture;
2. Online monitoring of water quality in wastewater treatment plants and industrial sectors;
3. Marine sea water quality online monitoring.
tandard Electrode Parameters
Temperature | Principle | Thermistor method |
Range | 0℃-80℃ | |
Accuracy | ±0.5℃ | |
pH Sensor | Principle | Glass electrode method |
Range | 0-14 pH | |
Accuracy | ±0.1 pH | |
Dimension | 28.7mm*195mm(Φ*L) | |
EC Conductivity Sensor | Principle | Conductivity cell method |
Range | 10us/cm-5000 us/cm(K=1) | |
Accuracy | ±3% or 3 us/cm, whichever is greater | |
Dimension | 28.7mm*195mm(Φ*L) | |
DO (Dissolved Oxygen) | Principle | Fluorescence |
Range | 0-20 mg/L;0-200% Saturation | |
Accuracy | ±3% or ±0.3 mg/L, whichever is greater | |
Dimension | 49.5mm*251.5mm(Φ*L) | |
Residual Chlorine Sensor (electrode method) | Principle | Constant voltage method |
Range | 0-2 mg/L,0-20 mg/L(optional) | |
Dimension | 13.5mm*178.5mm(Φ*L) | |
Turbidity Sensor (electrode method) | Principle | Light scattering method |
Range | 0.01-100NTU;0.01-4000NTU | |
Accuracy | Less than ±2% of the measure reading or ±0.1 NTU, whichever is greater | |
Dimension | 60mm*261mm(Φ*L) | |
Suspended Solids Sensor SS Sensor Sludge Concentration | Principle | Fluorescence |
Range | 0.01-20000mg/L;0.01-45000mg/L;0.01-120000mg/L | |
Accuracy | Less than the ±5% of measured value (Depending on the homogeneity of sludge) | |
Dimension | 60mm*261mm(Φ*L) | |
Chlorophyll Sensor | Principle | Fluorescence |
Range | 0-500 ug/L | |
Accuracy | ±5% of the signal level corresponding value of 1ppb Rhodamine B Dye | |
Dimension | 30*223mm(Φ*L) | |
Blue-green algae BA Sensor | Principle | Fluorescence |
Range | 0-300,000cells/mL | |
Accuracy | ±10% of the signal level corresponding value of 1ppb Rhodamine B Dye | |
Dimension | 30*223mm(Φ*L) | |
UVCOD Sensor | Principle | Spectroscopy |
Range | 0-2000mg/l COD (2mm optical path),0-1000mg/l COD (5mm optical path) 0-90mg/l COD (50mm optical path) | |
Accuracy | ±5%(KHP Standard solution) | |
Dimension | 69*365mm(Diam*L) | |
NO3 Sensor | Principle | Spectroscopy |
Range | 0.1-40mg/l (2mm optical path) | |
Accuracy | ±5% | |
Dimension | 69*365mm(Diam*L) | |
Ammonia nitrogen Sensor | Principle | Ion selection |
Range | NH4N:0.1-3000 mg/L, K+: 0.5- 5000 mg/L (Optional), PH:5-10 | |
Accuracy | NH4N:±5 % or ± 0.2 mg/L bigger; K+:±10 % or ±0.2 mg/L(Optional) Temp:±0.5℃; pH:±0.1 pH | |
Dimension | 55mm*342mm(Φ*L) |
WHY CHOOSE US:
Probest is a professional ISO9001 certificated manufacturer with many patents specializing in researching, developing, producing of water analysis instruments, including portable water analyzer, multi-parameter water quality analyzer, data acquisition and transmission terminal. The product can be applied to the fields of water quality monitoring of drinking water, waste water, surface water, aquaculture water, industrial process water, etc.
Probest is a reliable company including 30+ researcher, focusing on the development of sensor technology to make water analysis faster, simpler, greener and better.
Quality is our core advantages, providing stable and reliable water quality analysis.
Display | 7 inch touch screen with LED strong backlight, can operate in direct sunlight |
Power supply | AC power supply: 85-500VAC;DC power supply:9-36VDC |
Output | Standard 8 channels 4-20mA analog output. Program setting response parameters and response values |
Relay | Four-way relay, program setting response parameters and response values |
Communication protocol | Standard MODBUS RS485 communication for real-time transmission of measured value. Optional wireless communication method:4G:UDP/TCP NB:UDP |
Main Material | PA66+GF25+FR(top cover); aluminum powder dusting(lower shell) |
Storage Temperature | -20-70℃ |
Operation temperature | -15-60℃ |
Protective rate | IP65/ NEMA4X |
Dimension | 260mm*200mm*123.3mm(L*W*H) |
Weight | About 2.0KG |
China Factory Wholesale Testing Instrument Water Quality Analyzer Manufacturer
Measurement Principle:
MUC-200 multi-parameter transmitter can simultaneously monitor multiple different parameters according to different needs of customers, including temperature / PH / ORP / conductance / dissolved oxygen / turbidity / sludge concentration / chlorophyll / Blue-green algae / UVCOD / ammonia nitrogen and so on. The transmitter has a data storage function, and the user can also realize 4-20 mA analog output through interface configuration and calibration of the transmitter; realize relay control and digital communication.functions. Up to 7 sensor could be connected.
The multi-parameter transmitter can realize online monitoring of multiple different parameters at the same time through optional sensors according to different needs of customers, including temperature / PH / ORP / conductance / dissolved oxygen / turbidity / sludge concentration / chlorophyll / blue-green algae / UVCOD / UVNO3 / ion ammonia nitrogen / transparency / residual chlorine and other parameters. The transmitter software interface parameter display realizes self-adaptation,and has data storage and
Features:
1.Up to 7 sensors of our company can be connected at the same time to improve integration and reduce operation and maintenance costs
2. Strong versatility, all digital sensor interfaces are common, and analog sensors can be configured with different modules according to different sensor types
3. The plug and play of the sensor is realized, and the electrode installation and replacement are fast and convenient
4. With 7-inch color touch screen, the operation interface is simple, easy learn, reliable system, low maintenance;
5. pH, ORP, conductivity sensor cleaning and activation is simple, and the balance speed is fast
6. Dissolved oxygen sensor adopts breakthrough fluorescence method technology, basically no maintenance, and comes with NTC temperature compensation function
7. The turbidity, sludge concentration sensor uses ISO7027 standard method (infrared light scattering technology), which can eliminate the influence of the color of the sample, and can be equipped with a cleaning brush function
8. Chlorophyll sensor and blue-green algae sensor measure the target parameters based on the fluorescence of the pigment, which can be identified before the potential water bloom causes the impact, without the need for extraction or other treatment, rapid detection, to avoid the impact caused by the water samp
Applications:
1.Online monitoring of multi-parameter water quality in surface water, drinking water sources and aquaculture;
2. Online monitoring of water quality in wastewater treatment plants and industrial sectors;
3. Marine sea water quality online monitoring.
tandard Electrode Parameters
Temperature | Principle | Thermistor method |
Range | 0℃-80℃ | |
Accuracy | ±0.5℃ | |
pH Sensor | Principle | Glass electrode method |
Range | 0-14 pH | |
Accuracy | ±0.1 pH | |
Dimension | 28.7mm*195mm(Φ*L) | |
EC Conductivity Sensor | Principle | Conductivity cell method |
Range | 10us/cm-5000 us/cm(K=1) | |
Accuracy | ±3% or 3 us/cm, whichever is greater | |
Dimension | 28.7mm*195mm(Φ*L) | |
DO (Dissolved Oxygen) | Principle | Fluorescence |
Range | 0-20 mg/L;0-200% Saturation | |
Accuracy | ±3% or ±0.3 mg/L, whichever is greater | |
Dimension | 49.5mm*251.5mm(Φ*L) | |
Residual Chlorine Sensor (electrode method) | Principle | Constant voltage method |
Range | 0-2 mg/L,0-20 mg/L(optional) | |
Dimension | 13.5mm*178.5mm(Φ*L) | |
Turbidity Sensor (electrode method) | Principle | Light scattering method |
Range | 0.01-100NTU;0.01-4000NTU | |
Accuracy | Less than ±2% of the measure reading or ±0.1 NTU, whichever is greater | |
Dimension | 60mm*261mm(Φ*L) | |
Suspended Solids Sensor SS Sensor Sludge Concentration | Principle | Fluorescence |
Range | 0.01-20000mg/L;0.01-45000mg/L;0.01-120000mg/L | |
Accuracy | Less than the ±5% of measured value (Depending on the homogeneity of sludge) | |
Dimension | 60mm*261mm(Φ*L) | |
Chlorophyll Sensor | Principle | Fluorescence |
Range | 0-500 ug/L | |
Accuracy | ±5% of the signal level corresponding value of 1ppb Rhodamine B Dye | |
Dimension | 30*223mm(Φ*L) | |
Blue-green algae BA Sensor | Principle | Fluorescence |
Range | 0-300,000cells/mL | |
Accuracy | ±10% of the signal level corresponding value of 1ppb Rhodamine B Dye | |
Dimension | 30*223mm(Φ*L) | |
UVCOD Sensor | Principle | Spectroscopy |
Range | 0-2000mg/l COD (2mm optical path),0-1000mg/l COD (5mm optical path) 0-90mg/l COD (50mm optical path) | |
Accuracy | ±5%(KHP Standard solution) | |
Dimension | 69*365mm(Diam*L) | |
NO3 Sensor | Principle | Spectroscopy |
Range | 0.1-40mg/l (2mm optical path) | |
Accuracy | ±5% | |
Dimension | 69*365mm(Diam*L) | |
Ammonia nitrogen Sensor | Principle | Ion selection |
Range | NH4N:0.1-3000 mg/L, K+: 0.5- 5000 mg/L (Optional), PH:5-10 | |
Accuracy | NH4N:±5 % or ± 0.2 mg/L bigger; K+:±10 % or ±0.2 mg/L(Optional) Temp:±0.5℃; pH:±0.1 pH | |
Dimension | 55mm*342mm(Φ*L) |
WHY CHOOSE US:
Probest is a professional ISO9001 certificated manufacturer with many patents specializing in researching, developing, producing of water analysis instruments, including portable water analyzer, multi-parameter water quality analyzer, data acquisition and transmission terminal. The product can be applied to the fields of water quality monitoring of drinking water, waste water, surface water, aquaculture water, industrial process water, etc.
Probest is a reliable company including 30+ researcher, focusing on the development of sensor technology to make water analysis faster, simpler, greener and better.
Quality is our core advantages, providing stable and reliable water quality analysis.
Display | 7 inch touch screen with LED strong backlight, can operate in direct sunlight |
Power supply | AC power supply: 85-500VAC;DC power supply:9-36VDC |
Output | Standard 8 channels 4-20mA analog output. Program setting response parameters and response values |
Relay | Four-way relay, program setting response parameters and response values |
Communication protocol | Standard MODBUS RS485 communication for real-time transmission of measured value. Optional wireless communication method:4G:UDP/TCP NB:UDP |
Main Material | PA66+GF25+FR(top cover); aluminum powder dusting(lower shell) |
Storage Temperature | -20-70℃ |
Operation temperature | -15-60℃ |
Protective rate | IP65/ NEMA4X |
Dimension | 260mm*200mm*123.3mm(L*W*H) |