Availability: | |
---|---|
Quantity: | |
MUC200
PROBEST
MUC200 Muti-parameters Turbidity MLSS COD BOD Conducitivity DO PH Nitrite Ammonia Nitrogen Temp Water Quliaty Meter
Introduction
MUC-200 multi-parameter transmitter can simultaneously monitor multiple different parameters according to customers’ different needs, including Temperature / PH / ORP / Conductivity/Dissolved oxygen/Turbidity/Sludge concentration/Chlorophyll/ Blue-green algae / UVCOD / UVNO3 / Ionic ammonia nitrogen / Transparency / Residual chlorine and other parameters. It is widely used in water quality monitoring in wastewater treatment plants, waterworks, water stations, surface water, and industrial fields.
The transmitter software interface parameter display is adaptive, the operation interface menu is simple to set up, the user operation is convenient; the sensor is plug and play; the electrode installation and replacement is fast and convenient; various data transmission modes are optional, and the data storage and export are available.
Features
Up to 7 sensors can be connected to improve integration and reduce operating and maintenance costs.
High versatility, all digital sensor interfaces are common, and analog sensors can be configured with different modules according to different sensor types;
Sensor plugs and operates, quick and convenient electrode installation and replacement;
With 4-20mA, MODBUS RS485, wireless transmission and other data transmission methods;
7-inch color touch screen, easy operate, easy learn, reliable system and low maintenance;
With data storage and curve display function, master the dynamics of monitoring parameters;
Automatically prompt error and warning information, and upload alarm signals;
Have three levels of management authority;
Wall mounting or panel mounting;
With optional wireless data transmission module.
Technical Specifications
Display | 7 inch touch screen with LED strong backlight, can operate in direct sunlight |
Power supply | AC power supply: 85-500VAC;DC power supply:9-36VDC |
Output | Standard 8 channels 4-20mA analog output. Program setting response parameters and response values |
Relay | Four-way relay, program setting response parameters and response values |
Communication protocol | Standard MODBUS RS485 communication for real-time transmission of measured value. Optional wireless communication method:4G:UDP/TCP NB:UDP |
Main Material | PA66+GF25+FR (top cover); aluminum powder dusting (lower shell) |
Storage Temperature | -20-70℃ |
Operation temperature | -15-60℃ |
Protective rate | IP65/ NEMA4X |
Dimension | 260mm*200mm*123.3mm (L*W*H) |
Weight | About 2.0KG |
Technical Specifications
Display | 7 inch touch screen with LED strong backlight, can operate in direct sunlight |
Power supply | AC power supply: 85-500VAC or DC Power:9-36VDC |
Output | Standard 8 channels 4-20mA analog output. Program setting response parameters and response values |
Relay | Four-way relay, program setting response parameters and response values |
Communication protocol | Standard MODBUS RS485 communication for real-time transmission of measured value. Optional wireless communication method:4G: UDP/TCP NB: UDP |
Main Material | PA66+GF25+FR (top cover); aluminum powder dusting (lower shell) |
Storage Temperature | -20 to 70℃ |
Operation temperature | -15 to 60℃ |
Protective rate | IP65/ NEMA4X |
Dimension | 260mm*200mm*123.3mm (L*W*H) |
Weight | About 2.0KG |
Standard Electrode Parameters
Temperature | Principle | Thermistor method |
Range | 0℃-80℃ | |
Accuracy | ±0.5℃ | |
pH Sensor | Principle | Glass electrode method |
Range | 0-14 pH | |
Accuracy | ±0.1 pH | |
Dimension | 28.7mm*195mm(Φ*L) | |
EC Conductivity Sensor | Principle | Conductivity cell method |
Range | 10us/cm-5000 us/cm(K=1) | |
Accuracy | ±3% or 3 us/cm, the bigger one | |
Dimension | 28.7mm*195mm(Φ*L) | |
DO (Dissolved Oxygen) | Principle | Fluorescence |
Range | 0-20 mg/L;0-200% Saturation | |
Accuracy | ±3% or ±0.3 mg/L, the bigger one | |
Dimension | 49.5mm*251.5mm(Φ*L) | |
Residual Chlorine Sensor (electrode method) | Principle | constant voltage method |
Range | 0-2 mg/L,0-20 mg/L(optional) | |
Dimension | 13.5mm*178.5mm(Φ*L) | |
Turbidity Sensor (electrode method) | Principle | Light scattering method |
Range | 0.01-100NTU;0.01-4000NTU | |
Accuracy | < ±2% of the measure reading or ±0.1 NTU, the bigger one | |
Dimension | 60mm*261mm(Φ*L) | |
Suspended Solids Sensor SS Sensor Sludge Concentration | Principle | Fluorescence |
Range | 0.01-20000mg/L;0.01-45000mg/L;0.01-120000mg/L | |
Accuracy | < the ±5% of measured value. (Depending on the homogeneity of sludge) | |
Dimension | 60mm*261mm(Φ*L) | |
Chlorophyll Sensor | Principle | Fluorescence |
Range | 0-500 ug/L | |
Accuracy | ±5% of the signal level corresponding value of 1ppb Rhodamine B Dye | |
Dimension | 30*223mm(Φ*L) | |
Blue-green algae BA Sensor | Principle | Fluorescence |
Range | 0-300,000cells/mL | |
Accuracy | ±10% of the signal level corresponding value of 1ppb Rhodamine B Dye | |
Dimension | 30*223mm(Φ*L) | |
UVCOD Sensor | Principle | Spectroscopy |
Range | 0-2000mg/l COD (2mm optical path),0-1000mg/l COD (5mm optical path) 0-90mg/l COD (50mm optical path) | |
Accuracy | ±5%(KHP Standard solution) | |
Dimension | 69*365mm(Diam*L) | |
NO3 Sensor | Principle | Spectroscopy |
Range | 0.1-100.0mg/L(1mm optical path),0.1-50mg/l (2mm optical path) | |
Accuracy | ±5% | |
Dimension | 69*365mm(Diam*L) | |
Ammonia nitrogen Sensor | Principle | Ion selection |
Range | NH4N:0.1-3000 mg/L, K+: 0.5- 5000 mg/L (Optional), PH:5-10 | |
Accuracy | NH4N:±5 % or ± 0.2 mg/L bigger; K+:±10 % or ±0.2 mg/L(Optional) Temp:±0.5℃ ; pH:±0.1 pH | |
Dimension | 55mm*342mm(Φ*L) |
MUC200 Muti-parameters Turbidity MLSS COD BOD Conducitivity DO PH Nitrite Ammonia Nitrogen Temp Water Quliaty Meter
Introduction
MUC-200 multi-parameter transmitter can simultaneously monitor multiple different parameters according to customers’ different needs, including Temperature / PH / ORP / Conductivity/Dissolved oxygen/Turbidity/Sludge concentration/Chlorophyll/ Blue-green algae / UVCOD / UVNO3 / Ionic ammonia nitrogen / Transparency / Residual chlorine and other parameters. It is widely used in water quality monitoring in wastewater treatment plants, waterworks, water stations, surface water, and industrial fields.
The transmitter software interface parameter display is adaptive, the operation interface menu is simple to set up, the user operation is convenient; the sensor is plug and play; the electrode installation and replacement is fast and convenient; various data transmission modes are optional, and the data storage and export are available.
Features
Up to 7 sensors can be connected to improve integration and reduce operating and maintenance costs.
High versatility, all digital sensor interfaces are common, and analog sensors can be configured with different modules according to different sensor types;
Sensor plugs and operates, quick and convenient electrode installation and replacement;
With 4-20mA, MODBUS RS485, wireless transmission and other data transmission methods;
7-inch color touch screen, easy operate, easy learn, reliable system and low maintenance;
With data storage and curve display function, master the dynamics of monitoring parameters;
Automatically prompt error and warning information, and upload alarm signals;
Have three levels of management authority;
Wall mounting or panel mounting;
With optional wireless data transmission module.
Technical Specifications
Display | 7 inch touch screen with LED strong backlight, can operate in direct sunlight |
Power supply | AC power supply: 85-500VAC;DC power supply:9-36VDC |
Output | Standard 8 channels 4-20mA analog output. Program setting response parameters and response values |
Relay | Four-way relay, program setting response parameters and response values |
Communication protocol | Standard MODBUS RS485 communication for real-time transmission of measured value. Optional wireless communication method:4G:UDP/TCP NB:UDP |
Main Material | PA66+GF25+FR (top cover); aluminum powder dusting (lower shell) |
Storage Temperature | -20-70℃ |
Operation temperature | -15-60℃ |
Protective rate | IP65/ NEMA4X |
Dimension | 260mm*200mm*123.3mm (L*W*H) |
Weight | About 2.0KG |
Technical Specifications
Display | 7 inch touch screen with LED strong backlight, can operate in direct sunlight |
Power supply | AC power supply: 85-500VAC or DC Power:9-36VDC |
Output | Standard 8 channels 4-20mA analog output. Program setting response parameters and response values |
Relay | Four-way relay, program setting response parameters and response values |
Communication protocol | Standard MODBUS RS485 communication for real-time transmission of measured value. Optional wireless communication method:4G: UDP/TCP NB: UDP |
Main Material | PA66+GF25+FR (top cover); aluminum powder dusting (lower shell) |
Storage Temperature | -20 to 70℃ |
Operation temperature | -15 to 60℃ |
Protective rate | IP65/ NEMA4X |
Dimension | 260mm*200mm*123.3mm (L*W*H) |
Weight | About 2.0KG |
Standard Electrode Parameters
Temperature | Principle | Thermistor method |
Range | 0℃-80℃ | |
Accuracy | ±0.5℃ | |
pH Sensor | Principle | Glass electrode method |
Range | 0-14 pH | |
Accuracy | ±0.1 pH | |
Dimension | 28.7mm*195mm(Φ*L) | |
EC Conductivity Sensor | Principle | Conductivity cell method |
Range | 10us/cm-5000 us/cm(K=1) | |
Accuracy | ±3% or 3 us/cm, the bigger one | |
Dimension | 28.7mm*195mm(Φ*L) | |
DO (Dissolved Oxygen) | Principle | Fluorescence |
Range | 0-20 mg/L;0-200% Saturation | |
Accuracy | ±3% or ±0.3 mg/L, the bigger one | |
Dimension | 49.5mm*251.5mm(Φ*L) | |
Residual Chlorine Sensor (electrode method) | Principle | constant voltage method |
Range | 0-2 mg/L,0-20 mg/L(optional) | |
Dimension | 13.5mm*178.5mm(Φ*L) | |
Turbidity Sensor (electrode method) | Principle | Light scattering method |
Range | 0.01-100NTU;0.01-4000NTU | |
Accuracy | < ±2% of the measure reading or ±0.1 NTU, the bigger one | |
Dimension | 60mm*261mm(Φ*L) | |
Suspended Solids Sensor SS Sensor Sludge Concentration | Principle | Fluorescence |
Range | 0.01-20000mg/L;0.01-45000mg/L;0.01-120000mg/L | |
Accuracy | < the ±5% of measured value. (Depending on the homogeneity of sludge) | |
Dimension | 60mm*261mm(Φ*L) | |
Chlorophyll Sensor | Principle | Fluorescence |
Range | 0-500 ug/L | |
Accuracy | ±5% of the signal level corresponding value of 1ppb Rhodamine B Dye | |
Dimension | 30*223mm(Φ*L) | |
Blue-green algae BA Sensor | Principle | Fluorescence |
Range | 0-300,000cells/mL | |
Accuracy | ±10% of the signal level corresponding value of 1ppb Rhodamine B Dye | |
Dimension | 30*223mm(Φ*L) | |
UVCOD Sensor | Principle | Spectroscopy |
Range | 0-2000mg/l COD (2mm optical path),0-1000mg/l COD (5mm optical path) 0-90mg/l COD (50mm optical path) | |
Accuracy | ±5%(KHP Standard solution) | |
Dimension | 69*365mm(Diam*L) | |
NO3 Sensor | Principle | Spectroscopy |
Range | 0.1-100.0mg/L(1mm optical path),0.1-50mg/l (2mm optical path) | |
Accuracy | ±5% | |
Dimension | 69*365mm(Diam*L) | |
Ammonia nitrogen Sensor | Principle | Ion selection |
Range | NH4N:0.1-3000 mg/L, K+: 0.5- 5000 mg/L (Optional), PH:5-10 | |
Accuracy | NH4N:±5 % or ± 0.2 mg/L bigger; K+:±10 % or ±0.2 mg/L(Optional) Temp:±0.5℃ ; pH:±0.1 pH | |
Dimension | 55mm*342mm(Φ*L) |