PCM300-TP
PROBEST
90268090
n Main features
u Accurate sampling unit of syringe pump, the water sample and reagent take amount is more stable and accurate;
u Adopting a specially designed reference method, the slight displacement of the digestion tank and the mild pollution of the digestion tank do not affect the measured value;
u Accept remote control commands and has quality control functions such as zero check, standard check, parallel sample test, and standard recovery;
u With the process log record function of the analysis instrument, the data calculation is recorded once every hour, which can be stored for 3 years, and the data can be quickly exported by the U disk;
u With automatic fault diagnosis function, with abnormal information record and upload function, such as component fault, over-range alarm, over-standard alarm, lack of reagent alarm and other information;
u Have three levels of management authority;
u After abnormal reset and incoming call after power failure, the instrument automatically discharges the residual reactants in the instrument and automatically returns to the initial working state. With power-on alarm function, the instrument will generate alarm information when power is turned back on after power off;
u With overheat protection: the heating temperature is too high and the heater is automatically powered off;
u With 7-inch touch screen and simple operation interface, users are easy to learn, easy to operate and easy to maintain.
n Specification
Range | 0-1mg/L,0-4mg/L,0-10mg/L,0-25mg/L,0-50mg/L,0-100mg/L (Auto switch) |
Accuracy | Less than 1mg/L,no more than 0.1mg/L More than 1mg/L时,no more than ±10% |
Repeatability | no more than ±5% |
Resolution | 0.01mg/l |
Display | 7 inch display, operation interface |
Measurement cycle | 60~9999min adjustable mode(Min. 50mins)、punctually measurement mode, external trigger mode optional |
Calibration cycle | Manual or Auto mode, When auto. type, 1 day to 99 days optional |
Maintenance cycle | Usually once a month |
Power supply | 220VAC±10%,50HZ±10% |
Output | 4~20mA output |
Communication | MODBUS RS-232、RS-485 |
Relay | 4-Way Relay |
Environmental conditions | Temp adjustable indoor, recommended temperature +5 ~ 40 ° C Humidity ≤ 85% (no condensation) |
n Main features
u Accurate sampling unit of syringe pump, the water sample and reagent take amount is more stable and accurate;
u Adopting a specially designed reference method, the slight displacement of the digestion tank and the mild pollution of the digestion tank do not affect the measured value;
u Accept remote control commands and has quality control functions such as zero check, standard check, parallel sample test, and standard recovery;
u With the process log record function of the analysis instrument, the data calculation is recorded once every hour, which can be stored for 3 years, and the data can be quickly exported by the U disk;
u With automatic fault diagnosis function, with abnormal information record and upload function, such as component fault, over-range alarm, over-standard alarm, lack of reagent alarm and other information;
u Have three levels of management authority;
u After abnormal reset and incoming call after power failure, the instrument automatically discharges the residual reactants in the instrument and automatically returns to the initial working state. With power-on alarm function, the instrument will generate alarm information when power is turned back on after power off;
u With overheat protection: the heating temperature is too high and the heater is automatically powered off;
u With 7-inch touch screen and simple operation interface, users are easy to learn, easy to operate and easy to maintain.
n Specification
Range | 0-1mg/L,0-4mg/L,0-10mg/L,0-25mg/L,0-50mg/L,0-100mg/L (Auto switch) |
Accuracy | Less than 1mg/L,no more than 0.1mg/L More than 1mg/L时,no more than ±10% |
Repeatability | no more than ±5% |
Resolution | 0.01mg/l |
Display | 7 inch display, operation interface |
Measurement cycle | 60~9999min adjustable mode(Min. 50mins)、punctually measurement mode, external trigger mode optional |
Calibration cycle | Manual or Auto mode, When auto. type, 1 day to 99 days optional |
Maintenance cycle | Usually once a month |
Power supply | 220VAC±10%,50HZ±10% |
Output | 4~20mA output |
Communication | MODBUS RS-232、RS-485 |
Relay | 4-Way Relay |
Environmental conditions | Temp adjustable indoor, recommended temperature +5 ~ 40 ° C Humidity ≤ 85% (no condensation) |