PCM300-CODmn
PROBEST
90268090
n Main features
u Using the redox potential end point determination method, not affected by the chromaticity and turbidity of the water sample, and the measurement result is more accurate and true;
u Accurate sampling of syringe pump, the water sample and reagent take amount is more stable and accurate;
u Accept remote control commands and has quality control functions such as zero check, standard check, parallel sample test, and standard recovery;
u With the process log record function of the analysis instrument, the data calculation is recorded once every hour, which can be stored for 3 years, and the data can be quickly downloaded by the U disk;
u It has automatic fault diagnosis function, with abnormal information record and upload function, such as component fault, over-range alarm, over-standard alarm, lack of reagent alarm and other information;
u Have three levels of management authority;
u After abnormal reset and incoming call after power failure, the instrument automatically discharges the residual reactants in the instrument and automatically returns to the initial working state. With power-on alarm function, the instrument will generate alarm information when power is turned back on after power off;
u With overheat protection: the heating temperature is too high and the heater is automatically powered off;
u With 7-inch touch screen and simple operation interface, users are easy to learn, easy to operate and easy to maintain.
n Specification
Measurement Method | Acidic potassium permanganate redox titration |
Reaction end judge | Redox potential endpoint determination |
Test Range | 0-10mg/L 0-20mg/L (Auto switch) |
Repeatability | Not more than ±5% |
Accuracy | ±5% or 0.2mg/L big one |
Resolution | 0.01mg/l |
Display | 7 inch display, operation interface |
Measurement cycle | 60~9999min adjustable mode(Min. 40mins)、punctually measurement mode, external trigger mode optional |
Calibration cycle | Manual or Auto mode, When auto. type, 1 day to 99 days optional |
Maintenance cycle | Usually once a month 4~20mA |
power supply | 220VAC±10%,50HZ±10% |
Output | 4~20mA output |
Communication | MODBUS RS-232、RS-485 |
Relay | 4-Way Relay |
Environmental conditions | Temp adjustable indoor, recommended temperature +5 ~ 40 ° C Humidity ≤ 85% (no condensation) |
n Main features
u Using the redox potential end point determination method, not affected by the chromaticity and turbidity of the water sample, and the measurement result is more accurate and true;
u Accurate sampling of syringe pump, the water sample and reagent take amount is more stable and accurate;
u Accept remote control commands and has quality control functions such as zero check, standard check, parallel sample test, and standard recovery;
u With the process log record function of the analysis instrument, the data calculation is recorded once every hour, which can be stored for 3 years, and the data can be quickly downloaded by the U disk;
u It has automatic fault diagnosis function, with abnormal information record and upload function, such as component fault, over-range alarm, over-standard alarm, lack of reagent alarm and other information;
u Have three levels of management authority;
u After abnormal reset and incoming call after power failure, the instrument automatically discharges the residual reactants in the instrument and automatically returns to the initial working state. With power-on alarm function, the instrument will generate alarm information when power is turned back on after power off;
u With overheat protection: the heating temperature is too high and the heater is automatically powered off;
u With 7-inch touch screen and simple operation interface, users are easy to learn, easy to operate and easy to maintain.
n Specification
Measurement Method | Acidic potassium permanganate redox titration |
Reaction end judge | Redox potential endpoint determination |
Test Range | 0-10mg/L 0-20mg/L (Auto switch) |
Repeatability | Not more than ±5% |
Accuracy | ±5% or 0.2mg/L big one |
Resolution | 0.01mg/l |
Display | 7 inch display, operation interface |
Measurement cycle | 60~9999min adjustable mode(Min. 40mins)、punctually measurement mode, external trigger mode optional |
Calibration cycle | Manual or Auto mode, When auto. type, 1 day to 99 days optional |
Maintenance cycle | Usually once a month 4~20mA |
power supply | 220VAC±10%,50HZ±10% |
Output | 4~20mA output |
Communication | MODBUS RS-232、RS-485 |
Relay | 4-Way Relay |
Environmental conditions | Temp adjustable indoor, recommended temperature +5 ~ 40 ° C Humidity ≤ 85% (no condensation) |