Availability: | |
---|---|
Quantity: | |
PFDO-700
PROBEST
90268090
DO-700 Dissolved Oxygen analyzer adopts fluorescence method to measure dissolved oxygen. The cap of the sensor is coated with a luminescent material. Blue light from an LED illuminates the luminescent chemical. The luminescent chemical instantly becomes excited and releases red light. The time and intensity of red light are inversely proportional to the concentration of oxygen molecules, So the concentration of oxygen molecules is calculated.
n Features
u Won't produce oxygen consumption when measuring and no requirement of flow rate and stirring.
u Factory calibration, not need calibration for a year and can carry out field calibration.
u Digital sensor, high anti-jamming capacity and far transmission distance.
n Applications
DO online monitoring of different technological processes such as regulating reservoir, biochemical pool and effluent of sewage treatment plant.
DO online monitoring of water plant, surface water, industrial process water and aquaculture and etc.
n Technical Specifications
Measurement range | DO:0-20 mg/L or 0-200% saturation;Temperature:0-45℃ |
Measurement Accuracy | DO:±3% or ±0.3 mg/L, whichever is greater ; Temperature:±0.5℃ |
Pressure range | ≤0.3Mpa |
Calibration | Air automated calibration,sample calibration |
Main material | Body:SUS316L(fresh water),Titanium alloy(Ocean marine);Cover:PPS+ glass fiber;Cable:PUR |
Power supply | AC:85-500VAC (50/60HZ) DC:9~36VDC |
Output | 3-way 4-20mA |
Relay | Three-way relays, programmed response parameter and response value. |
Communication protocol | MODBUS RS485 |
Storage temperature | -15-60℃ |
Measuring temperature | 0-45℃(Non-freezing) |
Dimensions | Sensor:Dia49.5mm*L 251.5mm |
Transmitter:145*125*162mm(L*W*H) | |
Weight | Sensor:1.4KG;Transmitter:1.35KG |
Protective rate | Sensor:IP68/NEMA6P;Transmitter:IP65/ NEMA4X |
Cable length | Standard:10m, the maximum may be extended to 100m |
DO-700 Dissolved Oxygen analyzer adopts fluorescence method to measure dissolved oxygen. The cap of the sensor is coated with a luminescent material. Blue light from an LED illuminates the luminescent chemical. The luminescent chemical instantly becomes excited and releases red light. The time and intensity of red light are inversely proportional to the concentration of oxygen molecules, So the concentration of oxygen molecules is calculated.
n Features
u Won't produce oxygen consumption when measuring and no requirement of flow rate and stirring.
u Factory calibration, not need calibration for a year and can carry out field calibration.
u Digital sensor, high anti-jamming capacity and far transmission distance.
n Applications
DO online monitoring of different technological processes such as regulating reservoir, biochemical pool and effluent of sewage treatment plant.
DO online monitoring of water plant, surface water, industrial process water and aquaculture and etc.
n Technical Specifications
Measurement range | DO:0-20 mg/L or 0-200% saturation;Temperature:0-45℃ |
Measurement Accuracy | DO:±3% or ±0.3 mg/L, whichever is greater ; Temperature:±0.5℃ |
Pressure range | ≤0.3Mpa |
Calibration | Air automated calibration,sample calibration |
Main material | Body:SUS316L(fresh water),Titanium alloy(Ocean marine);Cover:PPS+ glass fiber;Cable:PUR |
Power supply | AC:85-500VAC (50/60HZ) DC:9~36VDC |
Output | 3-way 4-20mA |
Relay | Three-way relays, programmed response parameter and response value. |
Communication protocol | MODBUS RS485 |
Storage temperature | -15-60℃ |
Measuring temperature | 0-45℃(Non-freezing) |
Dimensions | Sensor:Dia49.5mm*L 251.5mm |
Transmitter:145*125*162mm(L*W*H) | |
Weight | Sensor:1.4KG;Transmitter:1.35KG |
Protective rate | Sensor:IP68/NEMA6P;Transmitter:IP65/ NEMA4X |
Cable length | Standard:10m, the maximum may be extended to 100m |