A reliable ISO direct manufacturer with CE ROHS certificate.     Please contact  WaterMonitor@probesti.com   WaterAnalyzer@probesti.com

PRODUCTS DETAIL

You are here: Home » Products » Online Analyzer » Colorimetric Water Analyzer » PCM200-PO4 Orthophosphate Water Quality Online Automatic Monitor Phosphorus Analysis in Wastewater

SITE SEARCH

PRODUCT CATEGORY

GET IN TOUCH

 Email: 
info@probesti.com
zhongweihua@probest.cn 
  Tel: +8613950412146
  Skype: zhongweihua 

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
sharethis sharing button

PCM200-PO4 Orthophosphate Water Quality Online Automatic Monitor Phosphorus Analysis in Wastewater

PROBEST New Analyzer for Orthophosphate provides accurate, reliable measurements for process control. The PO4 Analyzer features a revolutionary parts that dramatically reduces reagent use and maintenance requirements.
Orthophosphate Water Quality Online Automatic Monitor Principle Ammonium molybdate spectrophotometry. In an acidic medium, orthophosphate forms a colored complex with a color developer and a reducing agent. Its absorbance is measured at a specific wavelength and is proportional to the concentration of orthophosphate
Availability:
Quantity:
  • PCM200-PO4

  • PROBEST

PROBEST PO4 Orthophosphate Water Quality Online Automatic Monitor Phosphorus Analysis in Wastewater


PROBEST PO4 Orthophosphate Analyzer is an online, cabinet-style analyzer used for continuous monitoring of orthophosphate in a municipal water resource recovery facility.


PROBEST New Analyzer for Orthophosphate provides accurate, reliable measurements for process control. The PO4 Analyzer features a revolutionary part that dramatically reduces reagent use and maintenance requirements.


Principle 

Ammonium molybdate spectrophotometry. In an acidic medium, orthophosphate forms a colored complex with a color developer and a reducing agent. Its absorbance is measured at a specific wavelength and is proportional to the concentration of orthophosphate. 


Features 

The ten-way valve with sapphire valve core has high wear resistance, strong acid and alkali resistance, organic solvent resistance, long service life and high stability

The specially designed reference method is adopted, and the slight displacement and slight pollution of the digestion pool will not affect the measured value

Orthophosphate Analyzer has the function of waste liquid separation to achieve the separate discharge of high-concentration reaction waste liquid and low-concentration cleaning waste liquid

Orthophosphate Analyzer has a dynamic dilution function, which can automatically adjust the dilution multiple according to the range set on site

Orthophosphate Analyzer has built-in spike recovery, blank test, standard sample verification, zero point verification, span verification, parallel sample test and other quality control functions, and can realize automatic, manual, remote and other ways to start the quality control function

Orthophosphate Analyzer has the function of automatic fault diagnosis and abnormal information upload and recording, such as component failure, over-range alarm, over-standard alarm, reagent shortage alarm and other information;  It has overheating protection: If the heating temperature is too high, the heater will automatically shut down

Power on after abnormal reset and power failure, the instrument automatically discharges the residual reactants in the instrument and automatically returns to the initial working state. With power-on alarm function, the instrument will generate an alarm message when it is powered on again after power failure

Orthophosphate Analyzer has the function of recording the process log of the analytical instrument, the measurement data and the alarm information storage. It records the data once every hour and can store it for more than 5 years. The data can be quickly exported to a USB flash drive

Orthophosphate Analyzer has three levels of management authority. 


Application 

Online monitoring of orthophosphate in drinking water and surface water

Online monitoring of orthophosphate in municipal sewage outlets, pollution source discharge outlets, industrial wastewater outlets, secondary sedimentation tanks, and high-efficiency sedimentation tanks.


Technical Specification

Range: 0-10 mg/L, in P (customizable)

0-30 mg/L, in PO4 (customizable)

P and PO4 switchable with the operator and above permissions

Indication error: ≤±5% or ≤±0.005mg/L the bigger one

Detection limit: ≤0.01mg/L

Lower limit of quantification: ≤0.02mg/L

Repeatability: ≤2%

Resolution: 0.0001mg/L(Decimal places can be set from 2 to 4 digits)

Measurement cycle: 23 minutes

Display: 7-inch touch-screen

Measurement mode: Continuous mode, periodic mode (1h-30d adjustable), fixed-point mode, controlled mode, manual mode optional

Calibration mode: Manual calibration and automatic calibration modes

Maintenance cycle: Usually once a month

Power supply: 220VAC±10%,50HZ±10%

Output: 4-20mA outputs

Communication method: MODBUS RS-232、RS-485

Environmental conditions: Indoor(temperature adjustable), recommended temperature: +5-40 ℃ ; humidity ≤85% (no condensation)

Dimensions: 302*271*462mm(L*W*H)

Probest Honors and cases in water quality analyzer monitoring

Why choose Fuzhou Probest as wateranalyzer partner



Previous: 