Measurement Principle
Based on the UV absorption reaction by organic matter, the PUVCOD-900 Spectromete Organic On-Line Analyzer uses the 254 nm spectral absorption coefficient SAC254 to measure the content of soluble organic compound in the water and it can be converted to COD or BOD values under certain conditions. This
method allows continuous monitoring without any reagents.
² Direct-immersion probe measurement without taking sampling and pretreatment.
² No chemical reagents, no secondary pollution.
² Short response time for continuous measurement.
The sensor has an automatic cleaning function to reduce maintena
Features
Direct-immersion probe measurement without taking sampling and pretreatment.
No chemical reagents, no secondary pollution.
Short response time for continuous measurement.
The sensor has an automatic cleaning function to reduce maintenance time.
Application
Continuous monitoring of organic load during sewage treatment, online real-time monitoring of influent and effluent water quality of wastewater treatment plants.
Continuous on-line monitoring of surface water, industrial effluent, and fishery wastewater.
Model No. | UVCOD-900 Spectrometer cod test apparatus machine |
Measuring Range | COD (using KHP calibration): 0~2000mg/l COD (2mm) 0~1000mg/l COD (5mm); 0~90mg/l COD (50mm) BOD (using KHP calibration):0~1500mg/l BOD(2mm) 0~750mg/l BOD(5mm);0~60mg/l BOD(50mm) TOC(using KHP calibration):0~800mg/l TOC(2mm) 0~400mg/l TOC(5mm);0~36mg/l TOC(50mm) |
Accuracy | ±5% |
Measuring interval | Min one minute |
Pressure Range | ≤0.4Mpa |
Sensor material | SUS316L |
Power Supply | AC:85-500VAC (50/60HZ) DC:9~36VDC |
Output | 3-way 4-20mA |
Relay | Setting three-way relays,programmed response parameter and response value. |
Communication protocol | MODBUS RS485 |
Storage temperature | -15-65℃ |
Measuring temperature | 0-45℃ |
Dimensions | Sensor:Diam 69mm*Length 380mm |
Weight | Sensor:3.2KG; |
Protective rate | Sensor:IP68/NEMA6P; |
Cable length | Standard:10m,the maximum may be extended to 100m |
Suggested Backup spare parts | PGP-UVCOD : UVCOD Sensor Scraper |
Measurement Principle
Based on the UV absorption reaction by organic matter, the PUVCOD-900 Spectromete Organic On-Line Analyzer uses the 254 nm spectral absorption coefficient SAC254 to measure the content of soluble organic compound in the water and it can be converted to COD or BOD values under certain conditions. This
method allows continuous monitoring without any reagents.
² Direct-immersion probe measurement without taking sampling and pretreatment.
² No chemical reagents, no secondary pollution.
² Short response time for continuous measurement.
The sensor has an automatic cleaning function to reduce maintena
Features
Direct-immersion probe measurement without taking sampling and pretreatment.
No chemical reagents, no secondary pollution.
Short response time for continuous measurement.
The sensor has an automatic cleaning function to reduce maintenance time.
Application
Continuous monitoring of organic load during sewage treatment, online real-time monitoring of influent and effluent water quality of wastewater treatment plants.
Continuous on-line monitoring of surface water, industrial effluent, and fishery wastewater.
Model No. | UVCOD-900 Spectrometer cod test apparatus machine |
Measuring Range | COD (using KHP calibration): 0~2000mg/l COD (2mm) 0~1000mg/l COD (5mm); 0~90mg/l COD (50mm) BOD (using KHP calibration):0~1500mg/l BOD(2mm) 0~750mg/l BOD(5mm);0~60mg/l BOD(50mm) TOC(using KHP calibration):0~800mg/l TOC(2mm) 0~400mg/l TOC(5mm);0~36mg/l TOC(50mm) |
Accuracy | ±5% |
Measuring interval | Min one minute |
Pressure Range | ≤0.4Mpa |
Sensor material | SUS316L |
Power Supply | AC:85-500VAC (50/60HZ) DC:9~36VDC |
Output | 3-way 4-20mA |
Relay | Setting three-way relays,programmed response parameter and response value. |
Communication protocol | MODBUS RS485 |
Storage temperature | -15-65℃ |
Measuring temperature | 0-45℃ |
Dimensions | Sensor:Diam 69mm*Length 380mm |
Weight | Sensor:3.2KG; |
Protective rate | Sensor:IP68/NEMA6P; |
Cable length | Standard:10m,the maximum may be extended to 100m |